diff --git a/modules/calib/include/opencv2/calib.hpp b/modules/calib/include/opencv2/calib.hpp index 176c3212fe..e254dfc333 100644 --- a/modules/calib/include/opencv2/calib.hpp +++ b/modules/calib/include/opencv2/calib.hpp @@ -493,31 +493,31 @@ enum CameraModel { CALIB_MODEL_FISHEYE = 1, //!< Fisheye camera model }; -enum { CALIB_USE_INTRINSIC_GUESS = 0x00001, //!< Use user provided intrinsics as initial point for optimization. - CALIB_FIX_ASPECT_RATIO = 0x00002, //!< Use with CALIB_USE_INTRINSIC_GUESS. The ratio fx/fy stays the same as in the input cameraMatrix. - CALIB_FIX_PRINCIPAL_POINT = 0x00004, //!< The principal point (cx, cy) stays the same as in the input camera matrix. Image center is used as principal point, if CALIB_USE_INTRINSIC_GUESS is not set. - CALIB_ZERO_TANGENT_DIST = 0x00008, //!< For pinhole model only. Tangential distortion coefficients \f$(p_1, p_2)\f$ are set to zeros and stay zero. - CALIB_FIX_FOCAL_LENGTH = 0x00010, //!< Use with CALIB_USE_INTRINSIC_GUESS. The focal length (fx, fy) stays the same as in the input cameraMatrix. - CALIB_FIX_K1 = 0x00020, //!< The corresponding distortion coefficient is not changed during the optimization. 0 value is used, if CALIB_USE_INTRINSIC_GUESS is not set. - CALIB_FIX_K2 = 0x00040, //!< The corresponding distortion coefficient is not changed during the optimization. 0 value is used, if CALIB_USE_INTRINSIC_GUESS is not set. - CALIB_FIX_K3 = 0x00080, //!< The corresponding distortion coefficient is not changed during the optimization. 0 value is used, if CALIB_USE_INTRINSIC_GUESS is not set. - CALIB_FIX_K4 = 0x00800, //!< The corresponding distortion coefficient is not changed during the optimization. 0 value is used, if CALIB_USE_INTRINSIC_GUESS is not set. - CALIB_FIX_K5 = 0x01000, //!< For pinhole model only. The corresponding distortion coefficient is not changed during the optimization. 0 value is used, if CALIB_USE_INTRINSIC_GUESS is not set. - CALIB_FIX_K6 = 0x02000, //!< For pinhole model only. The corresponding distortion coefficient is not changed during the optimization. 0 value is used, if CALIB_USE_INTRINSIC_GUESS is not set. - CALIB_RATIONAL_MODEL = 0x04000, //!< For pinhole model only. Use rational distortion model with coefficients k4..k6. - CALIB_THIN_PRISM_MODEL = 0x08000, //!< For pinhole model only. Use thin prism distortion model with coefficients s1..s4. - CALIB_FIX_S1_S2_S3_S4 = 0x10000, //!< For pinhole model only. The thin prism distortion coefficients are not changed during the optimization. 0 value is used, if CALIB_USE_INTRINSIC_GUESS is not set. - CALIB_TILTED_MODEL = 0x40000, //!< For pinhole model only. Coefficients tauX and tauY are enabled in camera matrix. - CALIB_FIX_TAUX_TAUY = 0x80000, //!< For pinhole model only. The tauX and tauY coefficients are not changed during the optimization. 0 value is used, if CALIB_USE_INTRINSIC_GUESS is not set. - CALIB_USE_QR = 0x100000, //!< Use QR instead of SVD decomposition for solving. Faster but potentially less precise - CALIB_FIX_TANGENT_DIST = 0x200000, //!< For pinhole model only. Tangential distortion coefficients (p1,p2) are set to zeros and stay zero. +enum { CALIB_USE_INTRINSIC_GUESS = (1 << 0), //!< Use user provided intrinsics as initial point for optimization. + CALIB_FIX_ASPECT_RATIO = (1 << 1), //!< Use with CALIB_USE_INTRINSIC_GUESS. The ratio fx/fy stays the same as in the input cameraMatrix. + CALIB_FIX_PRINCIPAL_POINT = (1 << 2), //!< The principal point (cx, cy) stays the same as in the input camera matrix. Image center is used as principal point, if CALIB_USE_INTRINSIC_GUESS is not set. + CALIB_ZERO_TANGENT_DIST = (1 << 3), //!< For pinhole model only. Tangential distortion coefficients \f$(p_1, p_2)\f$ are set to zeros and stay zero. + CALIB_FIX_FOCAL_LENGTH = (1 << 4), //!< Use with CALIB_USE_INTRINSIC_GUESS. The focal length (fx, fy) stays the same as in the input cameraMatrix. + CALIB_FIX_K1 = (1 << 5), //!< The corresponding distortion coefficient is not changed during the optimization. 0 value is used, if CALIB_USE_INTRINSIC_GUESS is not set. + CALIB_FIX_K2 = (1 << 6), //!< The corresponding distortion coefficient is not changed during the optimization. 0 value is used, if CALIB_USE_INTRINSIC_GUESS is not set. + CALIB_FIX_K3 = (1 << 7), //!< The corresponding distortion coefficient is not changed during the optimization. 0 value is used, if CALIB_USE_INTRINSIC_GUESS is not set. + CALIB_FIX_K4 = (1 << 11), //!< The corresponding distortion coefficient is not changed during the optimization. 0 value is used, if CALIB_USE_INTRINSIC_GUESS is not set. + CALIB_FIX_K5 = (1 << 12), //!< For pinhole model only. The corresponding distortion coefficient is not changed during the optimization. 0 value is used, if CALIB_USE_INTRINSIC_GUESS is not set. + CALIB_FIX_K6 = (1 << 13), //!< For pinhole model only. The corresponding distortion coefficient is not changed during the optimization. 0 value is used, if CALIB_USE_INTRINSIC_GUESS is not set. + CALIB_RATIONAL_MODEL = (1 << 14), //!< For pinhole model only. Use rational distortion model with coefficients k4..k6. + CALIB_THIN_PRISM_MODEL = (1 << 15), //!< For pinhole model only. Use thin prism distortion model with coefficients s1..s4. + CALIB_FIX_S1_S2_S3_S4 = (1 << 16), //!< For pinhole model only. The thin prism distortion coefficients are not changed during the optimization. 0 value is used, if CALIB_USE_INTRINSIC_GUESS is not set. + CALIB_TILTED_MODEL = (1 << 18), //!< For pinhole model only. Coefficients tauX and tauY are enabled in camera matrix. + CALIB_FIX_TAUX_TAUY = (1 << 19), //!< For pinhole model only. The tauX and tauY coefficients are not changed during the optimization. 0 value is used, if CALIB_USE_INTRINSIC_GUESS is not set. + CALIB_USE_QR = (1 << 20), //!< Use QR instead of SVD decomposition for solving. Faster but potentially less precise + CALIB_FIX_TANGENT_DIST = (1 << 21), //!< For pinhole model only. Tangential distortion coefficients (p1,p2) are set to zeros and stay zero. // only for stereo - CALIB_FIX_INTRINSIC = 0x00100, //!< For stereo and milti-camera calibration only. Do not optimize cameras intrinsics - CALIB_SAME_FOCAL_LENGTH = 0x00200, //!< For stereo calibration only. Use the same focal length for cameras in pair. + CALIB_FIX_INTRINSIC = (1 << 8), //!< For stereo and milti-camera calibration only. Do not optimize cameras intrinsics + CALIB_SAME_FOCAL_LENGTH = (1 << 9), //!< For stereo calibration only. Use the same focal length for cameras in pair. // for stereo rectification - CALIB_ZERO_DISPARITY = 0x00400, //!< Deprecated synonim of @ref STEREO_ZERO_DISPARITY. See @ref stereoRectify. + CALIB_ZERO_DISPARITY = (1 << 10), //!< Deprecated synonim of @ref STEREO_ZERO_DISPARITY. See @ref stereoRectify. CALIB_USE_LU = (1 << 17), //!< use LU instead of SVD decomposition for solving. much faster but potentially less precise - CALIB_DISABLE_SCHUR_COMPLEMENT = (1 << 18), //!< disable Schur complement (use Bouguet calibration engine) + CALIB_DISABLE_SCHUR_COMPLEMENT = (1 << 27), //!< disable Schur complement (use Bouguet calibration engine) CALIB_USE_EXTRINSIC_GUESS = (1 << 22), //!< For stereo and multi-view calibration. Use user provided extrinsics (R, T) as initial point for optimization // fisheye only flags CALIB_RECOMPUTE_EXTRINSIC = (1 << 23), //!< For fisheye model only. Recompute board position on each calibration iteration